DIAB Site Information Form (site log) International GNSS Service See Instructions at: https://files.igs.org/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : Mario Aranha Date Prepared : 2024-11-07 Report Type : UPDATE If Update: Previous Site Log : diab_20241101.log Modified/Added Sections : 2 1. Site Identification of the GNSS Monument Site Name : Mt. Diablo Four Character ID : DIAB Monument Inscription : IERS DOMES Number : 44519M001 CDP Number : Monument Description : CONCRETE PILLAR Height of the Monument : Monument Foundation : Foundation Depth : Marker Description : Date Installed : 1998-05-21T23:45Z Geologic Characteristic : BEDROCK Bedrock Type : Bedrock Condition : Fracture Spacing : Fault zones nearby : Distance/activity : Additional Information : Reinforced concrete monument, approximately 0.3m : high. Monument is fastened to underlying rock : with cemented reinforcing rods. Threaded 5/8" : rod is cemented about 0.8m deep into concrete. : Antenna threads onto rod in reproducible manner. : Mark is top of washer at center of rod. 2. Site Location Information City or Town : Rural, near Concord State or Province : California Country : USA Tectonic Plate : Pacific-North America plate boundary Approximate Position (ITRF) X coordinate (m) : -2665288.2079 Y coordinate (m) : -4279361.5203 Z coordinate (m) : 3895422.8297 Latitude (N is +) : +375242.87 Longitude (E is +) : -1215456.28 Elevation (m,ellips.) : 990.4148 Additional Information : X,Y,Z is IGb14 realization of ITRF14 reference : frame, 2024.6066 reference epoch. 3. GNSS Receiver Information 3.1 Receiver Type : ASHTECH Z-XII3 Satellite System : GPS Serial Number : LP01387 Firmware Version : 1F60 Elevation Cutoff Setting : Date Installed : 1998-05-21T23:45Z Date Removed : 1999-07-21T22:12Z Temperature Stabiliz. : Additional Information : 3.2 Receiver Type : ASHTECH Z-XII3 Satellite System : GPS Serial Number : LP01387 Firmware Version : CC00 Elevation Cutoff Setting : Date Installed : 1999-07-21T22:12Z Date Removed : 2007-02-14T20:00Z Temperature Stabiliz. : Additional Information : 3.3 Receiver Type : TRIMBLE NETRS Satellite System : GPS Serial Number : 4610206093 Firmware Version : 1.1-3 Elevation Cutoff Setting : 0 deg Date Installed : 2007-02-14T20:18Z Date Removed : 2008-04-16T20:23Z Temperature Stabiliz. : Additional Information : 3.4 Receiver Type : TRIMBLE NETRS Satellite System : GPS Serial Number : 4610206093 Firmware Version : 1.1-5 Elevation Cutoff Setting : 0 deg Date Installed : 2008-04-16T20:23Z Date Removed : 2010-09-29T20:10Z Temperature Stabiliz. : Additional Information : 3.5 Receiver Type : TRIMBLE NETRS Satellite System : GPS Serial Number : 4610206093 Firmware Version : 1.3-0 Elevation Cutoff Setting : 0 deg Date Installed : 2010-09-29T20:10Z Date Removed : 2015-08-14T21:38Z Temperature Stabiliz. : Additional Information : 3.6 Receiver Type : TRIMBLE NETRS Satellite System : GPS Serial Number : 4610206093 Firmware Version : 1.3-2 Elevation Cutoff Setting : 0 deg Date Installed : 2015-08-14T21:38Z Date Removed : 2020-01-09T20:00Z Temperature Stabiliz. : Additional Information : 3.7 Receiver Type : SEPT POLARX5 Satellite System : GPS+GLO Serial Number : 3052109 Firmware Version : 5.3.0 Elevation Cutoff Setting : 0 deg Date Installed : 2020-01-09T20:00Z Date Removed : 2021-01-30T00:00Z Temperature Stabiliz. : Additional Information : 3.8 Receiver Type : SEPT POLARX5 Satellite System : GPS+GLO Serial Number : 3052109 Firmware Version : 5.4.0 Elevation Cutoff Setting : 0 deg Date Installed : 2021-01-30T00:00Z Date Removed : 2024-09-06T00:00Z Temperature Stabiliz. : Additional Information : 3.9 Receiver Type : SEPT POLARX5 Satellite System : GPS+GLO Serial Number : 3052109 Firmware Version : 5.5.0 Elevation Cutoff Setting : 0 deg Date Installed : 2024-09-06T00:00Z Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : Additional Information : 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS+GLO+GAL+BDS+QZSS+SBAS) Serial Number : (A20, but note the first A5 is used in SINEX) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : ASH700936D_M NONE Serial Number : 12739 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0837 Marker->ARP North Ecc(m) : Marker->ARP East Ecc(m) : Alignment from True N : 0 Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : Antenna Cable Length : Date Installed : 1998-05-21T23:45Z Date Removed : 1999-07-22T20:52Z Additional Information : 4.2 Antenna Type : ASH700936D_M SCIT Serial Number : 12739 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.1315 Marker->ARP North Ecc(m) : Marker->ARP East Ecc(m) : Alignment from True N : 0 Antenna Radome Type : SCIT Radome Serial Number : 00203 Antenna Cable Type : Antenna Cable Length : Date Installed : 1999-07-22T22:12Z Date Removed : 2015-08-14T19:30Z Additional Information : SCIGN Adaptor 0132 HI from previous refernce : mark Reference mark to base = 103.5 mm Base of : adapter to SCIGN mark = 19.685 mm SCIGN mark to : BPA = 8.3mm 4.3 Antenna Type : ASH700936D_M SCIT Serial Number : 12739 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0083 Marker->ARP North Ecc(m) : Marker->ARP East Ecc(m) : Alignment from True N : 0 Antenna Radome Type : SCIT Radome Serial Number : 3060 Antenna Cable Type : Antenna Cable Length : Date Installed : 2015-08-14T19:30Z Date Removed : 2023-02-03T00:00Z Additional Information : Configuration Change: Mounted on SCIGN adapter : s/n 0132; antenna height is standard value : relative to adapter reference point, a dimpled : nub; previous reference mark to adapter base = : 103.5mm; adapter base to adapter reference point : = 19.685mm; adapter reference point to BPA = : 8.3mm; Replaced broken dome only; retained base : plate 4.4 Antenna Type : SEPCHOKE_B3E6 SPKE Serial Number : 5190 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0083 Marker->ARP North Ecc(m) : Marker->ARP East Ecc(m) : Alignment from True N : 0 Antenna Radome Type : SPKE Radome Serial Number : Antenna Cable Type : Antenna Cable Length : Date Installed : 2023-02-03T00:00Z Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : UC Berkeley Preferred Abbreviation : BARD Mailing Address : University of California, Berkeley, 307 McCone : Hall #4760, Berkeley CA 94720-4760 Primary Contact Contact Name : Mario Aranha Telephone (primary) : 510-643-3898 Telephone (secondary) : Fax : E-mail : mario@seismo.berkeley.edu Secondary Contact Contact Name : Jonah Merritt Telephone (primary) : Telephone (secondary) : Fax : E-mail : jmerritt@berkeley.edu Additional Information : (multiple lines) 12. Responsible Agency (if different from 11.) Agency : Preferred Abbreviation : Mailing Address : Primary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : (multiple lines) 13. More Information Primary Data Center : NCEDC Secondary Data Center : URL for More Information : https://ncedc.org Hardcopy on File Site Map : (Y or URL) Site Diagram : (Y or URL) Horizon Mask : (Y or URL) Monument Description : (Y or URL) Site Pictures : (Y or URL) Additional Information : Antenna Graphics with Dimensions https://files.igs.org/pub/station/general/antenna.gra